{"id":1640,"date":"2021-03-04T08:31:10","date_gmt":"2021-03-04T08:31:10","guid":{"rendered":"http:\/\/admatel.com\/base\/?post_type=product&#038;p=1640"},"modified":"2021-11-11T15:08:27","modified_gmt":"2021-11-11T15:08:27","slug":"3d-ct-x-ray","status":"publish","type":"product","link":"https:\/\/admatel.com\/base\/product\/3d-ct-x-ray\/","title":{"rendered":"3D Computed Tomography (CT) X-Ray"},"content":{"rendered":"<div class=\"wptb-table-container wptb-table-2909\"><div class=\"wptb-table-container-matrix\" id=\"wptb-table-id-2909\" data-wptb-version=\"1.4.9\" data-wptb-pro-status=\"false\"><table class=\"wptb-preview-table wptb-element-main-table_setting-2905 edit-active\" data-reconstraction=\"1\" style=\"border: 1px solid rgb(209, 209, 209);\" data-wptb-table-tds-sum-max-width=\"132\" data-wptb-cells-width-auto-count=\"1\" data-wptb-extra-styles=\"LyogRW50ZXIgeW91ciBjdXN0b20gQ1NTIHJ1bGVzIGhlcmUgKi8=\" role=\"table\" data-wptb-header-background-color=\"#4A4A4AFF\" data-wptb-even-row-background-color=\"#FFFFFFFF\" data-wptb-odd-row-background-color=\"#FFFFFFFF\" data-table-columns=\"1\" data-wptb-horizontal-scroll-status=\"false\"><tbody><tr class=\"wptb-row\" style=\"background-color: rgb(74, 74, 74);\"><td class=\"wptb-cell\" style=\"border: 1px solid rgb(209, 209, 209);\" data-x-index=\"0\" data-y-index=\"0\" data-wptb-css-td-auto-width=\"true\"><div class=\"wptb-text-container wptb-ph-element wptb-element-text-51\" style=\"color: rgb(255, 255, 255);\"><div class=\"\" style=\"position: relative;\"><p><strong>Test Method<\/strong><\/p><\/div><\/div><\/td><\/tr><tr class=\"wptb-row\" style=\"background-color: rgb(255, 255, 255);\"><td class=\"wptb-cell\" data-y-index=\"1\" data-x-index=\"0\" style=\"border: 1px solid rgb(209, 209, 209);\" data-wptb-css-td-auto-width=\"true\"><div class=\"wptb-text-container wptb-ph-element wptb-element-text-1\" style=\"color: rgb(0, 0, 0);\"><div class=\"\" style=\"position: relative;\"><p><strong>2D X-ray \/ Digital Radiography Scan<\/strong><\/p><p><strong>3D X-ray\/ Computer Tomography Scan<\/strong><\/p><\/div><\/div><\/td><\/tr><tr class=\"wptb-row\" style=\"background-color: rgb(255, 255, 255);\"><td class=\"wptb-cell\" style=\"border: 1px solid rgb(209, 209, 209); background-color: rgb(74, 74, 74);\" data-x-index=\"0\" data-y-index=\"2\" data-wptb-css-td-auto-width=\"true\" data-wptb-own-bg-color=\"#4A4A4AFF\"><div class=\"wptb-text-container wptb-ph-element wptb-element-text-52\" style=\"color: rgb(255, 255, 255);\"><div class=\"\" style=\"position: relative;\"><p><strong>Sample Requirements<\/strong><\/p><\/div><\/div><\/td><\/tr><tr class=\"wptb-row\" style=\"background-color: rgb(255, 255, 255);\"><td class=\"wptb-cell\" style=\"border: 1px solid rgb(209, 209, 209);\" data-x-index=\"0\" data-y-index=\"3\" data-wptb-css-td-auto-width=\"true\"><div class=\"wptb-text-container wptb-ph-element wptb-element-text-2\" style=\"color: rgb(0, 0, 0); font-size: 15px;\"><div class=\"\" style=\"position: relative;\"><p><strong>Up to 80 cm diameter and 120 cm height<\/strong><\/p><p><strong>At most 150 kg<\/strong><\/p><p><strong>60 mm thickness steel<\/strong><\/p><p><strong>240 mm aluminum<\/strong><\/p><p><strong>No sample preparation needed (depends on sample specifications)<\/strong><\/p><p><\/p><\/div><grammarly-extension data-grammarly-shadow-root=\"true\" style=\"position: absolute; top: -1px; left: -1px; pointer-events: none; z-index: auto;\" class=\"cGcvT\"><\/grammarly-extension><grammarly-extension data-grammarly-shadow-root=\"true\" style=\"mix-blend-mode: darken; position: absolute; top: -1px; left: -1px; pointer-events: none; z-index: auto;\" class=\"cGcvT\"><\/grammarly-extension><grammarly-extension data-grammarly-shadow-root=\"true\" style=\"position: absolute; top: -1px; left: -1px; pointer-events: none; z-index: auto;\" class=\"cGcvT\"><\/grammarly-extension><grammarly-extension data-grammarly-shadow-root=\"true\" style=\"mix-blend-mode: darken; position: absolute; top: -1px; left: -1px; pointer-events: none; z-index: auto;\" class=\"cGcvT\"><\/grammarly-extension><\/div><\/td><\/tr><tr class=\"wptb-row\" style=\"background-color: rgb(255, 255, 255);\"><td class=\"wptb-cell\" style=\"border: 1px solid rgb(209, 209, 209); background-color: rgb(74, 74, 74);\" data-x-index=\"0\" data-y-index=\"4\" data-wptb-css-td-auto-width=\"true\" data-wptb-own-bg-color=\"#4A4A4AFF\"><div class=\"wptb-text-container wptb-ph-element wptb-element-text-4\" style=\"color: rgb(255, 255, 255);\"><div class=\"\" style=\"position: relative;\"><p><strong>Test Limitations<\/strong><\/p><\/div><\/div><\/td><\/tr><tr class=\"wptb-row\" style=\"background-color: rgb(255, 255, 255);\"><td class=\"wptb-cell\" style=\"border: 1px solid rgb(209, 209, 209);\" data-x-index=\"0\" data-y-index=\"5\" data-wptb-css-td-auto-width=\"true\"><div class=\"wptb-text-container wptb-ph-element wptb-element-text-46\" style=\"color: rgb(0, 0, 0);\"><div class=\"\" style=\"position: relative;\"><p><strong>For 2D X-ray \/ DR<\/strong><\/p><p><strong>Sample orientation: certain angles may visually negate the defect<\/strong><br><strong>material limitation (highly-densed materials, high and low dense material DR interactions)<\/strong><br><strong>sample thickness<\/strong><\/p><\/div><\/div><\/td><\/tr><tr class=\"wptb-row\" style=\"background-color: rgb(255, 255, 255);\"><td class=\"wptb-cell\" style=\"border: 1px solid rgb(209, 209, 209);\" data-x-index=\"0\" data-y-index=\"6\" data-wptb-css-td-auto-width=\"true\"><div class=\"wptb-text-container wptb-ph-element wptb-element-text-55\" style=\"color: rgb(0, 0, 0);\"><div class=\"\" style=\"position: relative;\"><p><strong>For 3D X-ray\/ CT<\/strong><\/p><p><strong>Sample orientation: flat top and bottom may induce artifact and less details<\/strong><br><strong>Material limitation (highly-densed materials, high and low dense material DR interactions: artifacts and rings)<\/strong><br><strong>Sample must remain motionless during scanning<\/strong><br><strong>NO LIVING SAMPLES<\/strong><\/p><\/div><\/div><\/td><\/tr><\/tbody><\/table><\/div><\/div>\n\n","protected":false},"excerpt":{"rendered":"<h6><strong>P17,400\/sample (P13,900 student rate)<br \/>\n<\/strong><\/h6>\n<p>3D Computed Tomography (CT) is a non-destructive scanning technology that allows you to view and inspect the external and internal structures of an object in 3D space. Computed Tomography works by taking hundreds or thousands of 2D Digital Radiography projections around a 360-degree rotation of an object. Proprietary algorithms are then used to reconstruct the 2D projections into a 3D CT volume, which will allow you to view and slice the part at any angle.<\/p>\n<ul>\n<li style=\"list-style-type: none;\">\n<ul>\n<li><strong>Real-time viewing for parameter optimization<br \/>\n<\/strong><\/li>\n<li><strong>Fast: Generates Digital Radiography scan in minutes; Computer Tomography scan could be less than an hour<br \/>\n<\/strong><\/li>\n<li><strong>Can measure as low as 0.2 microns (resolution)<br \/>\n<\/strong><\/li>\n<li><strong>SubPiX capability<br \/>\n<\/strong><\/li>\n<li><strong>Particle analysis<br \/>\n<\/strong><\/li>\n<li><strong>Linear Measurement\/ Measurements<br \/>\n<\/strong><\/li>\n<li><strong>CAD comparison<br \/>\n<\/strong><\/li>\n<li><strong>Material difference identification through density differences<br \/>\n<\/strong><\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<hr \/>\n<p><strong>Applications <\/strong><\/p>\n<p>Aerospace, Semiconductor, Automotives, Historical artifacts, powder particle analysis, Additive manufacturing, Steel\/Metal Casting, Electronics<\/p>\n","protected":false},"featured_media":1841,"template":"","meta":{"_kad_post_transparent":"default","_kad_post_title":"","_kad_post_layout":"default","_kad_post_sidebar_id":"","_kad_post_content_style":"default","_kad_post_vertical_padding":"default","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false},"product_cat":[39],"product_tag":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v20.7 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>3D Computed Tomography (CT) X-Ray | ADMATEL<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/admatel.com\/base\/our-services\/radiographic-testing\/3d-ct-x-ray\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"3D Computed Tomography (CT) X-Ray | ADMATEL\" \/>\n<meta property=\"og:url\" content=\"https:\/\/admatel.com\/base\/our-services\/radiographic-testing\/3d-ct-x-ray\/\" \/>\n<meta property=\"og:site_name\" content=\"ADMATEL\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/admatelofficial\" \/>\n<meta property=\"article:modified_time\" content=\"2021-11-11T15:08:27+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admatel.com\/base\/wp-content\/uploads\/2021\/03\/3D-Computed-Tomography-CT-X-Ray.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1080\" \/>\n\t<meta property=\"og:image:height\" content=\"1080\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/admatel.com\/base\/our-services\/radiographic-testing\/3d-ct-x-ray\/\",\"url\":\"https:\/\/admatel.com\/base\/our-services\/radiographic-testing\/3d-ct-x-ray\/\",\"name\":\"3D Computed Tomography (CT) X-Ray | ADMATEL\",\"isPartOf\":{\"@id\":\"https:\/\/admatel.com\/base\/#website\"},\"datePublished\":\"2021-03-04T08:31:10+00:00\",\"dateModified\":\"2021-11-11T15:08:27+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/admatel.com\/base\/our-services\/radiographic-testing\/3d-ct-x-ray\/#breadcrumb\"},\"inLanguage\":\"en\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/admatel.com\/base\/our-services\/radiographic-testing\/3d-ct-x-ray\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/admatel.com\/base\/our-services\/radiographic-testing\/3d-ct-x-ray\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/admatel.com\/base\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Services\",\"item\":\"https:\/\/admatel.com\/base\/?page_id=1051\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"3D Computed Tomography (CT) X-Ray\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/admatel.com\/base\/#website\",\"url\":\"https:\/\/admatel.com\/base\/\",\"name\":\"ADMATEL\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/admatel.com\/base\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/admatel.com\/base\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/admatel.com\/base\/#organization\",\"name\":\"ADMATEL\",\"url\":\"https:\/\/admatel.com\/base\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en\",\"@id\":\"https:\/\/admatel.com\/base\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/admatel.com\/base\/wp-content\/uploads\/2021\/02\/cropped-21192953_1434443383259960_2417890164514829800_n-1.png\",\"contentUrl\":\"https:\/\/admatel.com\/base\/wp-content\/uploads\/2021\/02\/cropped-21192953_1434443383259960_2417890164514829800_n-1.png\",\"width\":512,\"height\":512,\"caption\":\"ADMATEL\"},\"image\":{\"@id\":\"https:\/\/admatel.com\/base\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/admatelofficial\",\"https:\/\/www.linkedin.com\/in\/admatelofficial\/\",\"https:\/\/www.youtube.com\/channel\/UCaQNKvaiNPP-9ZoM2J5xvsg\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"3D Computed Tomography (CT) X-Ray | ADMATEL","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/admatel.com\/base\/our-services\/radiographic-testing\/3d-ct-x-ray\/","og_locale":"en_US","og_type":"article","og_title":"3D Computed Tomography (CT) X-Ray | ADMATEL","og_url":"https:\/\/admatel.com\/base\/our-services\/radiographic-testing\/3d-ct-x-ray\/","og_site_name":"ADMATEL","article_publisher":"https:\/\/www.facebook.com\/admatelofficial","article_modified_time":"2021-11-11T15:08:27+00:00","og_image":[{"width":1080,"height":1080,"url":"https:\/\/admatel.com\/base\/wp-content\/uploads\/2021\/03\/3D-Computed-Tomography-CT-X-Ray.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/admatel.com\/base\/our-services\/radiographic-testing\/3d-ct-x-ray\/","url":"https:\/\/admatel.com\/base\/our-services\/radiographic-testing\/3d-ct-x-ray\/","name":"3D Computed Tomography (CT) X-Ray | ADMATEL","isPartOf":{"@id":"https:\/\/admatel.com\/base\/#website"},"datePublished":"2021-03-04T08:31:10+00:00","dateModified":"2021-11-11T15:08:27+00:00","breadcrumb":{"@id":"https:\/\/admatel.com\/base\/our-services\/radiographic-testing\/3d-ct-x-ray\/#breadcrumb"},"inLanguage":"en","potentialAction":[{"@type":"ReadAction","target":["https:\/\/admatel.com\/base\/our-services\/radiographic-testing\/3d-ct-x-ray\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/admatel.com\/base\/our-services\/radiographic-testing\/3d-ct-x-ray\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admatel.com\/base\/"},{"@type":"ListItem","position":2,"name":"Services","item":"https:\/\/admatel.com\/base\/?page_id=1051"},{"@type":"ListItem","position":3,"name":"3D Computed Tomography (CT) X-Ray"}]},{"@type":"WebSite","@id":"https:\/\/admatel.com\/base\/#website","url":"https:\/\/admatel.com\/base\/","name":"ADMATEL","description":"","publisher":{"@id":"https:\/\/admatel.com\/base\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admatel.com\/base\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en"},{"@type":"Organization","@id":"https:\/\/admatel.com\/base\/#organization","name":"ADMATEL","url":"https:\/\/admatel.com\/base\/","logo":{"@type":"ImageObject","inLanguage":"en","@id":"https:\/\/admatel.com\/base\/#\/schema\/logo\/image\/","url":"https:\/\/admatel.com\/base\/wp-content\/uploads\/2021\/02\/cropped-21192953_1434443383259960_2417890164514829800_n-1.png","contentUrl":"https:\/\/admatel.com\/base\/wp-content\/uploads\/2021\/02\/cropped-21192953_1434443383259960_2417890164514829800_n-1.png","width":512,"height":512,"caption":"ADMATEL"},"image":{"@id":"https:\/\/admatel.com\/base\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/admatelofficial","https:\/\/www.linkedin.com\/in\/admatelofficial\/","https:\/\/www.youtube.com\/channel\/UCaQNKvaiNPP-9ZoM2J5xvsg"]}]}},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/admatel.com\/base\/wp-json\/wp\/v2\/product\/1640"}],"collection":[{"href":"https:\/\/admatel.com\/base\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/admatel.com\/base\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/admatel.com\/base\/wp-json\/wp\/v2\/media\/1841"}],"wp:attachment":[{"href":"https:\/\/admatel.com\/base\/wp-json\/wp\/v2\/media?parent=1640"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/admatel.com\/base\/wp-json\/wp\/v2\/product_cat?post=1640"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/admatel.com\/base\/wp-json\/wp\/v2\/product_tag?post=1640"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}